Skip to content
Vulnerability Path traversal CVE-2026-85114

Siemens .NET Client Library for SIMATIC S7 Webserver API path traversal CVE-2026-85114

Siemens .NET Client Library for SIMATIC S7 Webserver API fails to validate filenames during ticket downloads, allowing arbitrary file writes.

Reported by CISA

First reported Summary updated

Read the coverage
Public PoC
Not known
Exploited
Not known
CVSS
8.7 High

What happened

Siemens .NET Client Library for SIMATIC S7 Webserver API does not properly validate filenames received from remote servers during ticket downloads.1

An attacker who can manipulate the ticket response could write arbitrary files outside the intended download directory and, when overwriting is enabled, replace existing files accessible to the application.1

Who is affected

  • .NET Client Library for SIMATIC S7 Webserver API, All versions < V3.3.611

Is there a public exploit?

Not known None of the sources mentions public exploit code yet.

Exploited in the wild?

Not known None of the sources reports attacks using it so far.

What to do

  • Update to V3.3.61 or later version.1

For bug hunters

This is a path traversal flaw in a client library that downloads files from a remote server. Such bugs appear in file download, import and sync features where user-supplied filenames are used to build local paths. Test by supplying filenames with directory traversal sequences and observing whether files are written outside the intended directory. Also check whether overwriting existing files is possible.

What to test

  • Supply filenames containing ../ sequences in download requests and check for writes outside the target directory.
  • Test with absolute paths and encoded traversal sequences to bypass validation.
  • Enable overwriting and attempt to replace existing files accessible to the application.
  • Check error messages and logs for path disclosure after failed traversal attempts.

The Path traversal lesson Every Path traversal report

Written by bugbounty.wiki with AI from its source. Every statement above comes with a quote we checked against the source it cites (the numbers link to it); anything we could not check was left out. It can still be wrong, so read the coverage before relying on a detail.

Coverage

The article this story is based on. Each headline opens the outlet's own article.

  1. 1

    CISA

    Siemens .NET Client Library for SIMATIC S7 Webserver API
    “Industrial Control System Vulnerabilities , Industrial Control Systems”

Reports about Path traversal

View all

Disclosed reports of the same bug class, clearest first.

More news

View all

Other stories from the last month, Path traversal first.