Siemens SIMATIC products affected by NTLM relay authentication bypass (CVE-2026-58114)
Siemens SIMATIC products do not properly secure remote authentication with NTLM, allowing an on-path attacker to impersonate a legitimate user.
Reported by CISA
First reported Summary updated
- Public PoC
- Not known
- Exploited
- Not known
- CVSS
- 7.7 High
What happened
Siemens SIMATIC products contain an authentication bypass vulnerability that could let an on-path attacker take over a legitimate user's session and execute arbitrary code with the victim's privileges.1
The flaw is due to improper protection of remote user authentication using the deprecated NTLM protocol, enabling unauthenticated remote attackers in a machine-in-the-middle position to relay NTLM authentication and impersonate a legitimate user.1
The potential impact depends on which services are accessible, such as a SQL server used by WinCC.1
Who is affected
- SIMATIC BATCH V9.1, All versions1
- SIMATIC Information Server 2020, All versions1
- SIMATIC Information Server 2022, All versions1
- SIMATIC PCS 7 V9.1, All versions1
- SIMATIC Process Historian 2020, All versions1
- SIMATIC Process Historian 2022, All versions1
- SIMATIC WinCC Runtime Professional V17, All versions1
- SIMATIC WinCC Runtime Professional V18, All versions1
Is there a public exploit?
Not known None of the sources mentions public exploit code yet.
Exploited in the wild?
Not known None of the sources reports attacks using it so far.
What to do
- Manually configure the SQL Server Database to encrypt communication as described in Siemens support article 109818202.1
For bug hunters
This is an authentication bypass through NTLM relay, where a machine-in-the-middle attacker forwards NTLM authentication to impersonate a user. Such flaws appear in programs that expose Windows authentication over HTTP, SMB, LDAP or SQL, especially where NTLM is still enabled. Test for NTLM reflection and relay by capturing authentication attempts and replaying them to other services. Look for endpoints that accept NTLM without channel binding or extended protection.
What to test
- Check if NTLM authentication is accepted on web or API endpoints.
- Attempt to relay captured NTLM authentication to other in-scope services.
- Verify presence of Extended Protection for Authentication or channel binding.
- Test for NTLM reflection by sending authentication back to the same service.
Written by bugbounty.wiki with AI from its source. Every statement above comes with a quote we checked against the source it cites (the numbers link to it); anything we could not check was left out. It can still be wrong, so read the coverage before relying on a detail.