Targeting an industrial protocol gateway
The Anybus X-Gateway AB7832-F industrial protocol gateway has three vulnerabilities: a denial-of-service on port 7412, an unauthenticated reboot endpoint, and an unauthenticated configuration protocol (HICP). An attacker with network access could crash the device, reboot it repeatedly, or change its network settings, disrupting industrial communications.
Published on sensepost.com
Inside industrial systems (also known as Operational Technology, or OT), devices communicate with each other and can be accessed over IP using familiar IT protocols (such as SSH, web services, etc.), as well as with a variety of industrial network protocols. Among them, you may have heard of Modbus, maybe S7comm…
The full write-up lives on its author's site
It belongs to its author, so we link to it rather than copy it. The other two tabs are our own rewrites, checked against it.
Not written yet. The AI write-up for this write-up has not been written yet. The Original tab links to the source.
How it worked
Root cause
Likely the device's services were not designed with security in mind: they lack authentication, resource limits, and proper input handling.
Impact
An attacker could disrupt industrial operations by making the gateway unavailable or altering its configuration, potentially stopping critical network flows.
What the attacker needed
Network access to the device
How it was found
- Scan the device with nmap to discover open ports and services.
- Send 85 requests to port 7412 to crash all network services.
- Access the web interface without authentication and send a GET request to /slave/reboot.html to reboot the device.
- Use HICP protocol on port 3250/udp to change network settings without authentication.
Explained by bugbounty.wiki with AI from the original and checked against quotes from it; it can still be wrong. Read the original before relying on a detail.
Not written yet. The AI write-up for this write-up has not been written yet. The Original tab links to the source.
This report is about a small box that helps machines in a factory talk to each other using different languages (protocols). The researcher found that someone on the same network could easily make the box stop working or change its settings without logging in, which could stop the factory's machines from communicating.
What is DoS?
A request that exhausts resources or crashes a component. Many programs forbid testing it; reports usually show it from code, not by attacking.