Moxa SDS-3008 Series Industrial Ethernet Switch web server denial of service vulnerability
The web server on the Moxa SDS-3008 switch crashes when it receives an HTTP request that lacks the required empty line between headers and body. An attacker can send such a request to cause a denial of service, stopping the web server from accepting new connections until it restarts.
Originally disclosed on Cisco Talos
A denial of service vulnerability exists in the web server functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP message header can lead to denial of service.
The full write-up lives on its author's site
It belongs to its author, so we link to it rather than copy it. The other two tabs are our own rewrites, checked against it.
Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.
How it worked
Root cause
The web server does not properly validate the HTTP message format and crashes when the required empty line (CRLF) separating headers from the body is missing.
Impact
An attacker can cause a denial of service by crashing the web server, making the management interface unavailable until it automatically restarts.
What the attacker needed
Network access to the switch on port 443
The fix
The vendor released a patch on 2023-02-02.
How it was found
- Send an HTTP GET request to port 443 that includes the start line and a Host header but omits one of the required CRLF sequences.
- The web server thread terminates, and no new connections are accepted on ports 80 and 443.
- After several minutes, the device operating system restarts the web server in a new thread.
Explained by bugbounty.wiki with AI from the original and checked against quotes from it; it can still be wrong. Read the original before relying on a detail.
Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.
This report is about a denial-of-service bug in an industrial network switch. The switch runs a small web server for management, and it expects HTTP requests to follow a specific format. If a request is missing a required blank line, the server crashes and stops responding, so administrators cannot use the web interface until it restarts.
What is DoS?
A request that exhausts resources or crashes a component. Many programs forbid testing it; reports usually show it from code, not by attacking.