Schneider Electric IGSS Out-Of-Bounds Read Denial-of-Service Vulnerability
The IGSSDataServer process on TCP port 12401 does not properly validate user-supplied data, so a read can run past the end of an allocated buffer. A remote, unauthenticated attacker could use this to cause a denial-of-service condition on the IGSS application.
Originally disclosed on Zero Day Initiative
This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Schneider Electric IGSS. Authentication is not required to exploit this vulnerability.
The full write-up lives on its author's site
It belongs to its author, so we link to it rather than copy it. The other two tabs are our own rewrites, checked against it.
Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.
How it worked
Impact
A remote attacker without credentials could create a denial-of-service condition on affected IGSS installations.
What the attacker needed
Network access to TCP port 12401; no authentication needed
Explained by bugbounty.wiki with AI from the original and checked against quotes from it; it can still be wrong. Read the original before relying on a detail.
Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.
IGSS is industrial control software, and one of its background services listens for network connections on a fixed port. The service trusts the data it receives without checking its length, so it can read beyond the memory it set aside for that data. That can crash or hang the service, which is a denial of service: the software stops working for legitimate users.
What is DoS?
A request that exhausts resources or crashes a component. Many programs forbid testing it; reports usually show it from code, not by attacking.