Authentication bypass and potential RCE on the https://████ due to exposed Cisco TelePresence SX80 with default credentials

A Cisco TelePresence SX80 device was exposed online with default admin credentials, allowing an attacker to log in and fully control the device. The attacker could add startup scripts to achieve code execution and potentially intercept data or use the device as a backdoor.

sp1d3rs Follow

Originally disclosed on HackerOne

  • Triaged in 14 hours
  • Fixed in 5 months
  • Disclosed after 4.9 years

##Description Hello. I was able to identify another one Cisco TelePresence SX80 device located on the https://████████ right near the previous device ████ (after #684070 report I decided to check ████* range) According to the IP Info: https://ipinfo.io/AS257/████0/24 it belongs to ASN with ID

AS257 ███

The mentioned instance has same credentials admin:admin. This instance is different and less used, the logs reveals that last time device was used in 2017 year.

##POC https://████████ Login with admin:admin ███████ Since we are logged in as admin, we can completely control the device and all connections, and add our startup scripts via https://███████/web/scripts thus achiecing code execution.

##Suggested fix Change the credentials and likely you will need to reset the device to factory settings

Impact

Potential device compromise and code execution. This devices are used mainly for trainings, briefings, and demonstration rooms, as well as auditoriums, so attacker with full control of the device potentially can intercept the data (RCE potential is interesting, but ability to silently compromise the device and use it as backdoor can be much more harmful).

The original report as published on HackerOne, by sp1d3rs. Images and videos are our own copies; raw HTML is shown as text. View it on HackerOne.

Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.

How it worked

Impact

An attacker with full control of the device could intercept data and silently compromise it as a backdoor, though the report notes the device is less used and last active in 2017.

What the attacker needed

Device exposed to the internet; default admin credentials unchanged

The fix

The credentials should be changed and the device likely reset to factory settings.

How it was found

  1. Find the Cisco TelePresence SX80 device on the internet.
  2. Log in using the default admin credentials.
  3. Access the web scripts page to add startup scripts.

Explained by bugbounty.wiki with AI from the original and checked against quotes from it; it can still be wrong. Read the original before relying on a detail.

Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.

A video conferencing device was left on the internet with default admin credentials. Anyone who found it could log in as administrator and change its settings, including adding scripts that run at startup, giving full control over the device and its connections.

What is RCE?

Running the attacker's code on the target's servers: through command or code injection, unsafe deserialisation or template injection.

More by sp1d3rs

View all

62 more disclosed reports, best first.

More from U.S. Dept Of Defense

View all

The newest disclosed reports for this program.

Similar reports

View all

Same bug class and techniques, clearest first.

Remote code execution

The lesson behind this report.

Running the attacker's code on the target's servers: through command or code injection, unsafe deserialisation or template injection.