Skip to content
RCE Advisory Advanced CVE-2021-41365

Microsoft Defender for IoT Remote Code Execution Vulnerability (CVE-2021-41365)

An authenticated user of the on-premises management console could exploit a flaw to achieve remote code execution. The text does not describe the technical mechanism, only that low privileges and an integration token are needed.

Anonymous working with Trend Micro Zero Day Initiative Follow

Originally disclosed on Microsoft

High 8.8 View original

FAQ

What version of Microsoft Defender for IoT has the update that protects from this vulnerability? Version 10.5.2 and above. What is the action required to take the update? You need to update to the latest Microsoft Defender for IoT software version. See the Update the software version section of Manage the on-premises management console . What is Microsoft Defender for IoT? Microsoft Defender for IoT is a unified security solution for identifying IoT/OT devices, vulnerabilities, and threats. It enables you to secure your entire IoT/OT environment, whether you need to protect existing IoT/OT devices or build security into new IoT innovations. See Microsoft Defender for IoT for more information.

FAQ

According to the CVSS metric, privileges required is low (PR:L). What does that mean for this vulnerability? Successful exploitation of this vulnerability requires an attacker to authenticate to the management console appliance and to have an integration token documented here: Defender for IoT sensor and management console APIs .

Microsoft Defender for IoT

Microsoft Defender for IoT

Microsoft

Microsoft

The original report as published on the Microsoft Security Response Center, by Anonymous working with Trend Micro Zero Day Initiative. Images and videos are our own copies; raw HTML is shown as text. View it on Microsoft Security Response Center.

Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.

How it worked

Impact

An authenticated attacker with an integration token could run code on the appliance, though the text gives no further detail on scope.

What the attacker needed

Authenticated console account; an integration token

The fix

It was fixed by updating to Microsoft Defender for IoT version 10.5.2 or above.

Explained by bugbounty.wiki with AI from the original and checked against quotes from it; it can still be wrong. Read the original before relying on a detail.

Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.

This is a security advisory for a flaw in Microsoft Defender for IoT, software that watches over industrial and connected devices. Someone with a normal login to the management console could, in theory, run their own code on the appliance, which is a serious outcome. The advisory does not explain how the flaw works, only that a patch exists.

What is RCE?

Running the attacker's code on the target's servers: through command or code injection, unsafe deserialisation or template injection.

More by Anonymous working with Trend Micro Zero Day Initiative

View all

19 more disclosed reports, best first.

More from Microsoft

View all

The newest disclosed reports for this program.

Similar reports

View all

Same bug class and techniques, clearest first.

Remote code execution

The lesson behind this report.

Running the attacker's code on the target's servers: through command or code injection, unsafe deserialisation or template injection.