Exploited RCE CVE-2026-116779

CVE-2026-116779: SignalWire FreeSWITCH code injection exploited in the wild

FreeSWITCH before 1.11.3 lets an accepted SIP MESSAGE run API commands, and CISA added the flaw to its known exploited list.

Reported by CISA KEV

First reported Summary updated

Read the coverage
Public PoC
Not known
Exploited
Yes, KEV
CVSS
9.8 Critical

What happened

In FreeSWITCH before 1.11.3, the sofia_presence_handle_sip_i_message() function split the To user of an inbound SIP MESSAGE on a plus sign and treated the left side as a chat protocol selector.NVD

Choosing the api chat proto reached switch_api_execute(), so a peer whose MESSAGE was accepted could run FreeSWITCH API commands, including operating-system command sinks, with the daemon's privileges.NVD

Inbound chat is enabled on the stock internal and external profiles, and any authenticated profile account is enough; stock directory users without password material can also remove that barrier in affected configurations.NVD

The flaw allows configuration and credential disclosure, arbitrary call control and command execution, and exploitation has been observed in the wild.NVD

CISA added CVE-2026-116779 to its catalogue of known exploited vulnerabilities on 9 November 2026.KEV

Who is affected

  • SignalWire FreeSWITCH, prior to 1.11.3NVD

Is there a public exploit?

Not known None of the sources mentions public exploit code yet.

Exploited in the wild?

Yes Exploitation of CVE-2026-116779 has been observed in the wild.NVD CISA added CVE-2026-116779 to its catalogue of known exploited vulnerabilities on 9 November 2026, with US federal agencies required to act by 12 November 2026.

What to do

  • Update FreeSWITCH to version 1.11.3, where the issue is fixed.NVD
  • Apply mitigations following vendor instructions, in line with CISA BOD 26-04 guidance.KEV

Vendor advisories and patches: github.com/signalwire/freeswitch/commit/7015f6a73ab3d67fed5f..., github.com/signalwire/freeswitch/pull/3135

For bug hunters

This is a code injection flaw in SIP message handling, where user-controlled input reaches an API command dispatcher. In bounty programmes, similar bugs appear in telephony gateways, chat or presence services and any endpoint that parses protocol fields into internal commands. Look for places where a delimiter in a header or address is used to pick a handler or protocol. Test whether an authenticated low-privilege account can reach privileged command execution through crafted messages.

What to test

  • Send SIP MESSAGE requests with a plus sign in the To user and vary the left-hand token.
  • Check whether chat protocol selection can reach API or operating-system command execution.
  • Test with a stock directory user that has no password material.
  • Try the internal and external SIP profiles with an authenticated account.

The RCE lesson Every RCE report

Written by bugbounty.wiki with AI from its source. Every statement above comes with a quote we checked against the source it cites (the numbers link to it); anything we could not check was left out. It can still be wrong, so read the coverage before relying on a detail.

Coverage

The article this story is based on. Each headline opens the outlet's own article.

  1. 1

Reports about RCE

View all

Disclosed reports of the same bug class, clearest first.

More news

View all

Other stories from the last month, RCE first.