Skip to content
Vulnerability RCE CVE-2026-109830

Siemens meta-iot2050 firmware update tool command injection, CVE-2026-109830

Siemens meta-iot2050 from V01.03.01 has a command injection flaw in its firmware update tool; no fix is available yet.

Reported by CISA

First reported Summary updated

Read the coverage
Public PoC
Not known
Exploited
Not known
CVSS
7.0 High

What happened

Siemens meta-iot2050 versions from V01.03.01 contain an OS command injection vulnerability in the firmware update tool.1

The affected devices take parts from a configuration file and execute them without checking, so an attacker who can manipulate that file could run arbitrary commands as root.1

Siemens ProductCERT reported the vulnerability to CISA.1

Who is affected

  • Siemens meta-iot2050, >= V01.03.011

Is there a public exploit?

Not known None of the sources mentions public exploit code yet.

Exploited in the wild?

Not known None of the sources reports attacks using it so far.

What to do

  • No fix is currently available; Siemens recommends mitigations for products where fixes are not yet available.1
  • Protect network access to devices with appropriate mechanisms and configure the environment according to Siemens' operational guidelines for Industrial Security.1
  • Minimise network exposure for control system devices and ensure they are not accessible from the internet.1

For bug hunters

This is an OS command injection (CWE-78) where values from a configuration file reach a shell without sanitisation. In bounty programmes, look for features that parse user-supplied configuration, such as firmware or update tools, import/export routines and device management interfaces. Test whether crafted values in configuration fields are executed as commands, and check the privilege level the process runs at.

What to test

  • Submit configuration files containing shell metacharacters in fields used by update or import tools.
  • Check whether command output or timing differences reveal execution of injected commands.
  • Test configuration parsing endpoints for injection when the process runs as root or a privileged user.
  • Review firmware update workflows for unsanitised values passed to system calls.

The RCE lesson Every RCE report

Written by bugbounty.wiki with AI from its source. Every statement above comes with a quote we checked against the source it cites (the numbers link to it); anything we could not check was left out. It can still be wrong, so read the coverage before relying on a detail.

Coverage

The article this story is based on. Each headline opens the outlet's own article.

  1. 1

    CISA

    Siemens meta-iot2050
    “Industrial Control System Vulnerabilities , Industrial Control Systems”

Reports about RCE

View all

Disclosed reports of the same bug class, clearest first.

More news

View all

Other stories from the last month, RCE first.