Siemens meta-iot2050 firmware update tool command injection, CVE-2026-109830
Siemens meta-iot2050 from V01.03.01 has a command injection flaw in its firmware update tool; no fix is available yet.
Reported by CISA
First reported Summary updated
- Public PoC
- Not known
- Exploited
- Not known
- CVSS
- 7.0 High
What happened
Siemens meta-iot2050 versions from V01.03.01 contain an OS command injection vulnerability in the firmware update tool.1
The affected devices take parts from a configuration file and execute them without checking, so an attacker who can manipulate that file could run arbitrary commands as root.1
Siemens ProductCERT reported the vulnerability to CISA.1
Who is affected
- Siemens meta-iot2050, >= V01.03.011
Is there a public exploit?
Not known None of the sources mentions public exploit code yet.
Exploited in the wild?
Not known None of the sources reports attacks using it so far.
What to do
- No fix is currently available; Siemens recommends mitigations for products where fixes are not yet available.1
- Protect network access to devices with appropriate mechanisms and configure the environment according to Siemens' operational guidelines for Industrial Security.1
- Minimise network exposure for control system devices and ensure they are not accessible from the internet.1
For bug hunters
This is an OS command injection (CWE-78) where values from a configuration file reach a shell without sanitisation. In bounty programmes, look for features that parse user-supplied configuration, such as firmware or update tools, import/export routines and device management interfaces. Test whether crafted values in configuration fields are executed as commands, and check the privilege level the process runs at.
What to test
- Submit configuration files containing shell metacharacters in fields used by update or import tools.
- Check whether command output or timing differences reveal execution of injected commands.
- Test configuration parsing endpoints for injection when the process runs as root or a privileged user.
- Review firmware update workflows for unsanitised values passed to system calls.
Written by bugbounty.wiki with AI from its source. Every statement above comes with a quote we checked against the source it cites (the numbers link to it); anything we could not check was left out. It can still be wrong, so read the coverage before relying on a detail.
Coverage
The article this story is based on. Each headline opens the outlet's own article.
-