Skip to content
Vulnerability RCE CVE-2026-59082

Siemens SIMATIC WinCC flaw CVE-2026-59082 allows code execution via active content

Siemens SIMATIC WinCC versions V7.5, V8.0 and V8.1 implicitly execute active content when opening files, enabling arbitrary code execution.

Reported by CISA

First reported Summary updated

Read the coverage
Public PoC
Not known
Exploited
Not known
CVSS
8.5 High

What happened

Siemens SIMATIC WinCC versions V7.5, V8.0 and V8.1 contain an implicit active content execution vulnerability in Graphics Designer.1

The flaw could let an attacker cause arbitrary code execution on the device.1

The vulnerability is tracked as CVE-2026-59082 and is classified as CWE-357, insufficient UI warning of dangerous operations.1

Who is affected

  • SIMATIC WinCC V7.5, All versions1
  • SIMATIC WinCC V8.0, All versions1
  • SIMATIC WinCC V8.1, All versions1

Is there a public exploit?

Not known None of the sources mentions public exploit code yet.

Exploited in the wild?

Not known None of the sources reports attacks using it so far.

What to do

  • Only open files from trusted sources.1
  • Operate the affected product only by qualified personnel following the relevant documentation, warning notices and safety instructions.1
  • Protect network access to devices with appropriate mechanisms.1

For bug hunters

This is a local code execution issue caused by implicit execution of active content when opening files, a weakness in how applications handle untrusted file content. Bug bounty hunters should look for file parsers or viewers that automatically execute embedded scripts, macros or active objects without clear warnings. Test by supplying crafted files to in-scope applications and observing whether code runs or dangerous operations occur without user consent. Focus on desktop and industrial software that opens project or document files.

What to test

  • Upload or open files with embedded active content in file viewers or editors.
  • Check whether the application warns before executing macros or scripts.
  • Test project files from untrusted sources for automatic code execution.
  • Look for missing UI warnings when opening files with active components.

The RCE lesson Every RCE report

Written by bugbounty.wiki with AI from its source. Every statement above comes with a quote we checked against the source it cites (the numbers link to it); anything we could not check was left out. It can still be wrong, so read the coverage before relying on a detail.

Coverage

The article this story is based on. Each headline opens the outlet's own article.

  1. 1

    CISA

    Siemens SIMATIC WinCC
    “Industrial Control System Vulnerabilities , Industrial Control Systems”

Reports about RCE

View all

Disclosed reports of the same bug class, clearest first.

More news

View all

Other stories from the last month, RCE first.