D-Link DIR-1935 SetWebFilterSetting WebFilterURLs Command Injection Remote Code Execution Vulnerability
The web management portal of D-Link DIR-1935 routers fails to validate the WebFilterURLs parameter in SetWebFilterSetting requests before passing it to a system call. A network-adjacent attacker who bypasses authentication can execute arbitrary code as root.
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of D-Link DIR-1935 routers. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The full write-up lives on its author's site
It belongs to its author, so we link to it rather than copy it. The other two tabs are our own rewrites, checked against it.
Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.
How it worked
Root cause
The web management process passes the user-supplied WebFilterURLs value to a system call without validating or sanitising it.
Impact
A network-adjacent attacker could execute arbitrary code as root on the router, though authentication is required and must first be bypassed.
What the attacker needed
Network-adjacent access; authentication bypass
The fix
D-Link issued an update to correct the vulnerability.
Explained by bugbounty.wiki with AI from the original and checked against quotes from it; it can still be wrong. Read the original before relying on a detail.
Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.
A router's web admin page accepts a setting for web filter URLs. The router takes that text and runs it as part of a system command without checking it first. An attacker on the same network can sneak in extra commands and run them with the highest privileges on the router.
What is RCE?
Running the attacker's code on the target's servers: through command or code injection, unsafe deserialisation or template injection.