coTURN server unsafe telnet admin portal default configuration vulnerability
The coTURN server by default runs an unauthenticated telnet admin portal on the loopback interface, allowing anyone who can reach that port to gain administrator access to the TURN server configuration. This can lead to further attacks such as firewall bypass.
Originally disclosed on Cisco Talos
An exploitable unsafe default configuration vulnerability exists in the TURN server function of coTURN prior to version 4.5.0.9. By default, the TURN server runs an unauthenticated telnet admin portal on the loopback interface.
The full write-up lives on its author's site
It belongs to its author, so we link to it rather than copy it. The other two tabs are our own rewrites, checked against it.
Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.
How it worked
Root cause
The default configuration enables an unauthenticated telnet admin portal on the loopback interface.
Impact
An attacker who can access the telnet port could gain administrator access to the TURN server, potentially bypassing firewalls and conducting further attacks.
What the attacker needed
Access to loopback interface or local network
The fix
The vulnerability was fixed in version 4.5.0.9; users should upgrade or disable the telnet portal or set a password.
Explained by bugbounty.wiki with AI from the original and checked against quotes from it; it can still be wrong. Read the original before relying on a detail.
Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.
A TURN server helps devices communicate through firewalls. coTURN, a popular TURN server, includes an admin interface that by default has no password and listens only on the local machine. If an attacker can reach that local port, they can take full control of the server.
What is Misconfiguration?
Settings left unsafe: exposed panels, open storage buckets, debug modes, default credentials.