Open Automation Software OAS Platform OAS Engine configuration management improper resource allocation vulnerability
An authenticated application user can create arbitrary directories on the underlying system through the OAS Engine configuration management functionality. This allows a user who is not authorised on the underlying system to create directories anywhere the OAS service account has write access.
An improper resource allocation vulnerability exists in the OAS Engine configuration management functionality of Open Automation Software OAS Platform v18.00.0072. A specially crafted series of network requests can lead to creation of an arbitrary directory.
The full write-up lives on its author's site
It belongs to its author, so we link to it rather than copy it. The other two tabs are our own rewrites, checked against it.
Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.
How it worked
Root cause
Likely the configuration management feature does not restrict directory creation to safe locations, allowing an authenticated application user to specify any path.
Impact
An authenticated application user could create directories anywhere the OAS service account has write access, potentially disrupting the system or enabling further attacks.
What the attacker needed
Authenticated OAS application user; network access to OAS Engine
The fix
Access to the OAS Engine configuration server should be restricted to authorised hosts, and the OAS user's read/write access should be limited to safe locations; the vendor released a fixed version v19.
Explained by bugbounty.wiki with AI from the original and checked against quotes from it; it can still be wrong. Read the original before relying on a detail.
Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.
The OAS Platform is software that connects industrial devices and databases. It has its own user accounts, separate from the operating system accounts. A logged-in OAS user can use a configuration tool to create folders on the server's disk, even if that person has no operating system account on the server.
What is Misconfiguration?
Settings left unsafe: exposed panels, open storage buckets, debug modes, default credentials.