Delta Electronics InfraSuite Device Master CtrlLayerNWCmd_FileOperation Opcode 512 Directory Traversal Remote Code Execution Vulnerability
The CtrlLayerNWCmd_FileOperation function in Delta Electronics InfraSuite Device Master fails to validate a user-supplied file path, allowing a remote attacker to perform directory traversal. This can lead to remote code execution with administrator privileges, though authentication is required and can be bypassed.
Originally disclosed on Zero Day Initiative
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics InfraSuite Device Master. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The full write-up lives on its author's site
It belongs to its author, so we link to it rather than copy it. The other two tabs are our own rewrites, checked against it.
Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.
How it worked
Root cause
Likely, the software does not properly sanitise the fileName input before using it in file operations, allowing path traversal.
Impact
An attacker could execute arbitrary code with administrator privileges, but authentication is required and can be bypassed.
What the attacker needed
Authentication (bypassable); network access to the service
The fix
The vendor has issued an update to correct this vulnerability.
Explained by bugbounty.wiki with AI from the original and checked against quotes from it; it can still be wrong. Read the original before relying on a detail.
Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.
This vulnerability is in a software called Delta Electronics InfraSuite Device Master. It lets an attacker send a specially crafted file path that can escape the intended folder and run malicious code on the server. The attacker needs to log in first, but the login can be bypassed.
What is Path traversal?
Input that builds a file path escapes the intended folder, reading or writing files the application should never touch.