Delta Industrial Automation InfraSuite Device Master CtrlLayerNWCmd_FileOperation Directory Traversal Information Disclosure Vulnerability
The CtrlLayerNWCmd_FileOperation function in Delta InfraSuite Device Master fails to validate a user-supplied file path, allowing an unauthenticated remote attacker to read sensitive files with administrator privileges.
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Delta Industrial Automation InfraSuite Device Master. Authentication is not required to exploit this vulnerability.
The full write-up lives on its author's site
It belongs to its author, so we link to it rather than copy it. The other two tabs are our own rewrites, checked against it.
Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.
How it worked
Root cause
Likely the application fails to sanitise or restrict the fileName parameter before using it in file operations, allowing path traversal sequences.
Impact
An unauthenticated remote attacker could disclose sensitive information in the context of an administrator.
What the attacker needed
Network access to the affected service; no authentication required
The fix
The vendor has issued an update to correct this vulnerability.
Explained by bugbounty.wiki with AI from the original and checked against quotes from it; it can still be wrong. Read the original before relying on a detail.
Not written yet. The AI write-up for this report has not been written yet. The Original tab links to the source.
This is a directory traversal bug. The software takes a file name from a user and uses it to open a file without checking that the name stays inside the intended folder. An attacker can use special characters like '..' to climb out of that folder and read other files on the system, even without logging in.
What is Path traversal?
Input that builds a file path escapes the intended folder, reading or writing files the application should never touch.